AquiTron AT-MGS refrigerant gas detection

AquiTron AT-MGS refrigerant gas detection

Aquitron AT-MGS-400 series gas detectors:
Detection for refrigerants, toxic and combustible gases

AT-MGS-400-2

AT-MGS-400 Series Gas Detection Sensors

Gas detection solution for safety compliance

  • Mobile app interface for intuitive commissioning and maintenance
  • Plug-and-play pre-calibrated sensor modules
  • Pre-calibrated & temperature compensated sensors for increased reliability
  • On-board audible and visual alarms for refrigerant safety compliance with
    BS EN378, BREEAM Pol 01 & ASHRAE 15
Click for Datasheet – Product & Design Guide

AT-MGS-features

AT-MGS-402

AT-MGS-402 Gas Detection Alarm Panel – Controller

Two-channel controller for refrigerant, toxic and combustible gas detection

  • Refrigerant gas detection alarm panel – controller
  • Centralised power and alarming for 1 and 2 AT-MGS-410 gas detectors
  • 3 Leak volt free alarm relays: Low alarm, High alarm, Fault
  • Modbus RTU communications, Master / Slave capability provides seamless integration from all connected gas detectors
  • Audible and visual alarms enable compliance with BS EN378, BREEAM Pol 01 & AHSRAE 15 / no additional hardware required
Click for Datasheet – Product & Design Guide
Click for Datasheet
Click for Installation & Operation Instructions
AT-MGS-408

AT-MGS-408 Gas Detection Alarm Panel – Controller

This is a centralised controller for refrigerant safety compliance

  • Centralised power and alarming for up to 8 gas sensors
  • Alphanumeric display & tri-colour LEDs
  • Displays real-time status / gas measurement for all connected gas detectors
  • Modbus RTU master and slave capability
  • 3 Leak volt free alarm relays: Low alarm, High alarm, Fault
  • Event logging via SD Card
  • Integrated sounder / beacon 87dB (A) at 10cm
  • Optional sounder / beacon, 85-95 dB at 61cm, four colours available
  • Approvals: CE, UL, CSA, IEC EN 61010-1
Click for Datasheet – Product & Design Guide
Click for Datasheet
Click for Installation & Operation Instructions
AT-MGS-410

AT-MGS-410 Gas Sensor

Basic model with integrated 72dB (A) audible alarm

  • Stand-alone sensor or can be connected to a BMS or AquiTron AT-MGS-402 or AT-MGS-408 control panel
  • IP66 rated enclosure
  • Modbus RTU output
  • Audible & visual alarms
  • Bluetooth connectivity to the MGS-400 Companion App
  • Sensor life of 4–6 years with plug and play pre-calibrated sensor modules
  • Meets BS EN378, BREEAM Pol 01 and ASHRAE 15 requirements
Click for Quick Start Guide
AT-MGS-450

AT-MGS-450 Gas Sensor

  • Stand-alone sensor or can be connected to a BMS or AquiTron AT-MGS-408 control panel
  • IP41 or IP66 rated enclosure options
  • 3 Leak volt free alarm relays: Low alarm, High alarm, Fault
  • 4-20mA Analogue output
  • Bluetooth connectivity to the MGS-400 Companion App
  • Modbus RTU output
  • Audible & visual alarms
  • Sensor life of 4-6 years with plug and play pre-calibrated sensor modules
  • Meets BS EN378, BREEAM Pol 01 and ASHRAE 15 requirements
Click for Quick Start Guide
AT-MGS-460

AT-MGS-460 Gas Sensor

  • Stand-alone model with remote sensor (5m cable included, can go up to 20m) or can be connected to the AquiTron AT-MGS-408 control panel
  • IP66 rated housings
  • 3 Leak volt free alarm relays: Low alarm, High alarm, Fault
  • 4-20mA Analogue output
  • Bluetooth connectivity to the MGS-400 Companion App
  • Modbus RTU output
  • Audible & visual alarms
  • Sensor life of 4-6 years with plug and play pre-calibrated sensor modules
  • Meets BS EN378, BREEAM Pol 01 and ASHRAE 15 requirements
Click for Quick Start Guide

Aquilar Intuitive Mobile Interface

MGS-400 Companion App

The App allows easy configuration & setup of the AT-MGS 410, 450 and 460 series of sensors via Bluetooth connectivity

Intuitive Configuration, Maintenance & Calibration:

  • Bluetooth connectivity
  • Available for Android & iOS
  • Enable all configuration & data extraction
  • Intuitive interface
  • No training required

Main Screen / Gas Measurement:

  • Current gas level reading, ppm
  • Gas type
  • Alarm status indication via coloured circle surrounding gas reading and via text
  • Acknowledge alarms
  • Instrument serial number
  • Menu options for calibration, view details, disconnect and restart

Quickly Test Device Outputs:

  • Enable manual function test of outputs
  • LED colour
  • Buzzer function
  • Relay activation
  • Analogue output level & mode

AT-MGS-550

AT-MGS-550 Industrial Gas Detector

Dual gas detector for safety compliance

  • Flexible two-sensor capability, local and / or remote
  • Audible & visual alarms
  • Two analogue outputs and Modbus RTU interface
  • 3 fully configurable, user-assignable relays
  • One user-interface platform for all sensor types
  • Magnetic wand enables easy, non-intrusive configuration / calibration
  • IP66-rated ABS enclosure provides protection from dust and water
  • Meets BS EN378, BREEAM Pol 01 and ASHRAE 15 requirements
Click for Datasheet – Product & Design Guide
Click for Datasheet
Ductwork Mounting Kit Installation Instructions

Refrigeration and air conditioning gas leak detection applications

Data centres

Refrigeration in data centres is important to prevent overheating of electrical equipment. Effective refrigerant leak detection can help to ensure efficient cooling by minimizing leaks, protecting valuable equipment and data. Sensors are available which are not affected by cleaning agents typically used in these environments.

Machinery rooms

Refrigerant leak detection in machinery rooms is typically required for regulatory compliance with codes including BS EN378, F-Gas and ASHRAE 15. Cost-effective refrigerant leak detection can help businesses to comply with legislation and identify when refrigerant leaks must be repaired.

Hotel rooms, apartments & occupied spaces (VRF / VRV)

Modern refrigerant systems are designed to be efficient and leak free, but improper installations, inadvertent damage, or mechanical wear can result in leaks over time. The AT-G-ALERT refrigerant detector helps to keep the occupants comfortable in the conditioned spaces by providing early warning of refrigerant leaks over the service life of the HVAC system.

Find out more about the AT-G-ALERT refrigerant detector